ISOFLUX-IFX-MA-03
ISOFLUX, model IFX-Mx-03 is an ultrasound energy and flow meter which can be used to measure energy consumption for fluids, even other than water, in closed or open ring energy systems, and also for calculating water consumption.
The main features and advantages are: all the meters are MI004 certified according to European standard EN1434, IFX-M4-03. The meters can be used for calculating thermal or cooling energy, and for measuring the flow rate.
The IFX-Mx-03 range starts from DN15 up to DN50 in a compact version.
Two additional impulse inputs for external (sanitary) flow meters.
Alarm functions can be integrated.
Integrated data logger: daily recordings.
Integrated battery power supply.
ISOFLUX-IFX-MA-04
ISOFLUX, model IFX-Mx-04, is an ultrasound energy and flow meter which can be used for measuring energy consumption for fluids, also other than water in closed or open ring energy systems and also for water consumption.
The main features and advantages of the IFX series are:
all meters are certified MI004 to European standard EN1434 up to DN100, IFX-M4-04.
The meters can be used to calculate the thermal or cooling energy, and to measure the flow rate.
The IFX-Mx-04 range starts from DN25 up to DN200 in a compact or remote version.
ISOFLUX-IFX-M4-E3
The IFX-M4-03 Isoflux ultrasonic energy meter has been used for the measurement of energy consumption for fluids, also other than water, in closed or open ring energy systems, and also for the calculation of the consumption of the water. The instrument is designed to measure and record data in two separate registers for heating and cooling for the measurement of the flow rate from DN15 up to DN50 in a compact version. It can be used for the measurement of commercial energy consumption, for local or district heating systems, in the home environment, office buildings, centralized energy systems and similar projects.
TRANSIT TIME ULTRASONIC FLOWMETER
The meters work on the principle of the difference in the transit time of ultrasound pulses.
The big advantage is in the installation, since it is not necessary to cut the pipe. The sensors are simply bandaged on the external surface of the tube, which is why pressure and aggressiveness of the liquid to be measured are not a problem for the meter. The system measures bidirectionally and is suitable for clean or moderately soiled liquids.
POLLUCOM E
The Amtron E30 meter is used to measure thermal energy consumption in systems that transport hot and cold water.
POLLUCOM M
The compact PolluCom meter is used to measure energy consumption in heating or cooling circuits.